Tolerances and testing procedures:
Length Tolerances
Type of reservoir Reservoir with extruded PE wrapper Tolerances
35(L)mm¡ã125(L)mm ¡Ó0.6mm
10(L)mm¡ã35(L)mm ¡Ó0.8mm
   
Method:
Individual values
Length gauge
Precision of the measuring device: 0.01mm
Diameter
Diameter of reservoir Tolerances
¡Õ6.0mm ¡Ó0.1mm
6.1mm-16.0mm ¡Ó0.20mm
¡Ö16.0mm ¡Ó0.25mm
Method:
Individual values
Dial gauge-Measuring Device
Precision of the measuring device: 0.01mm
Out-of- Roundness (Oval)
Diameter of reservoir Tolerances
¡Õ6.0mm Max. 0.7mm
6.1mm-16.0mm Max. 0.9mm
¡Ö16.0mm Max. 1.0mm
Method:
Individual values
Dial gauge-Measuring Device
Precision of the measuring device: 0.01mm
Weight Tolerance
Type of reservoir Reservoir with extruded PE wrapper Tolerances
4mm£r¡ã6mm£r + 0.02 g¡Ð 0 g
6.1mm£r¡ã12mm£r ¡Ó0.03 g
12.1mm£r¡ã25mm£r ¡Ó3 ¢M
Method:
Ten units are weighed
The value in grams is divided by ten and the values for fiber and wrappers are separately indicated
Electronic balance
Precision of the measuring device: 0.01 g
Absorption Tolerances
Type of reservoir Reservoir with extruded PE wrapper Tolerances
4mm£r¡ã25mm£r ¡Ó10¢M
   
   
Method:
The reservoir are immersed vertically to a depth of 5 mm in deionized water
for 5 minutes
They are weighed. Without wiping the outside surface.
The test is made by manually.
Precision of the measuring device: 0.01 g
   
 
   
 